Internal Remote Scanner

RIN01GBx00 - Internal Remote Scanner without keypad - Std ABS Plastic. This unit is required only when the wall to which the Internal Remote Scanner is fitted is either too thick or constructed of metal. It is designed to be installed on the non-secure side. It is essentially a support element, working in parallel to the electronics of the Impro-Scan Range of products.

RIN02GBx00 - Internal Remote Scanner with keypad - Std ABS Plastic for Flexi-Scan E and Multi-Scan IV only


Main Applications:

  • Inside buildings, apartments, etc., where two points of reading access are needed, e.g. one inside and one outside to open the same door

  • In cases where walls have high metal content or are too thick

  • To allow the electronics cabinet to be fitted into a secure (lockable) area, and the reading scanner to be remotely situated.

  • When anti-passback is required, a remote scanner is required on scanner channel B.

  • This remote scanner can be used with in the following products:

Flexi-Scan - all versions
Link-Scan Controller
Link-Scan Terminal
Imp-Scan
Gen-Scan
Multi Scan IV Terminals

 

Remote Scanners:

  • Connection for the remote scanners can be made to two Molex connectors labeled JP1 and JP2. 6-Core screened cable with 0,2 mm conductors is recommended. The unit can be mounted up to 25 m away but not closer than 500 mm to its main unit. JP1 is parallel with the internal scanner. JP2 is a separate input (on dual channel systems).

  • BE AWARE that a Remote Scanner connected to JP1 will be the opposite sense to a Remote Scanner connected to JP2. i.e. If channel 1 (JP1) is designated as an ENTRANCE door, then channel 2 (JP2) is and EXIT door and vice versa. This allows for correct operations of anti-passback.

  •  

    Specifications:

    • Size: L = 161 mm, B = 90 mm, H = 45 mm
    • Positioning: Can be mounted up to 25 m away from any unit

    • 3 LEDs to indicate:
      Access Allowed - green
      Present Tag - yellow
      Access Denied - red

    • Coil frequency: The coil frequency must be the same as for the product to which it is connected viz. 281 kHz or 125 kHz

    • Operating environment: -25°C to +70°C

    We Ship Nationwide